Tripp Lite TAA-Compliant 11kW 3-Phase Monitored PDU, 220/230V (30-C13 & 6-C19), IEC-309 16A Red, 380/400V Input, 10ft Cord, 0U Vertical

  • Brand : Tripp Lite
  • Product name : TAA-Compliant 11kW 3-Phase Monitored PDU, 220/230V (30-C13 & 6-C19), IEC-309 16A Red, 380/400V Input, 10ft Cord, 0U Vertical
  • Product code : PDU3XVN10G16TAA
  • Category : Power Distribution Units (PDUs)
  • Data-sheet quality : created/standardized by Icecat
  • Product views : 30221
  • Info modified on : 14 Jun 2024 20:32:37
  • Product Brochure/Datasheet (0.4 MB)
  • Warranty: : 2-year limited warranty
  • Long product name Tripp Lite TAA-Compliant 11kW 3-Phase Monitored PDU, 220/230V (30-C13 & 6-C19), IEC-309 16A Red, 380/400V Input, 10ft Cord, 0U Vertical :

    TAA-Compliant 11kW 3-Phase Monitored PDU, 220/230V (30-C13 & 6-C19), IEC-309 16A Red, 380/400V Input, 10ft Cord, 0U Vertical

  • Tripp Lite TAA-Compliant 11kW 3-Phase Monitored PDU, 220/230V (30-C13 & 6-C19), IEC-309 16A Red, 380/400V Input, 10ft Cord, 0U Vertical :

    - Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
    - Monitored 11kW 3 Phase 380/400V input, 220/230V output PDU; 178cm 0U vertical rackmount
    - Reports voltage, frequency and load per-phase via built in ethernet interface
    - Visual current meter; Toolless button-mount installation
    - IEC-309 Red 16A (3P+N+E) 380/400V 3 phase input; 3m line cord
    - 30 C13 & 6 C19 single phase 230V outlets; Included cord retention brackets
    - Temperature, humidity and contact closure monitoring options

    Tripp Lite 3 phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip.

    - Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
    - 11kW 3 phase 380/400V input, 220/230V output Monitored Power Distribution Unit (PDU) with built-in web/network interface
    - Attached IEC-309 Red 16A (3P+N+E) 380/400V 3 phase input plug with 3m cord
    - 0U / 178cm vertical form factor supports installation in 2 or 4 post equipment racks
    - 36 total 220/230V outlets (30 C13, 6 C19) arranged in three single phase output load banks
    - Lighted display with scroll-button reports power consumption in amps for all 3 loading banks, IP-address self-identification and 180 degree display rotation for overhead or raised floor power feeds.
    - Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading per-phase via network or secure web browser interface with options for user specified alarm and notification thresholds
    - Supports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
    - DHCP/Manual configuration support
    - 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks
    - Real-time clock backup maintains the time of day and date even if the PDU is not powered on
    - Tiered access privileges allow an administrator and a guest to login via web browser for monitoring
    - Alert notifications via email or SNMP traps offer immediate event notification
    - Firmware upgrade ability supports future product enhancements.
    - Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
    - Fully compatible with FREE PowerAlert Network Management System / NMS Software
    - Included cord retention brackets keep vital network equipment plugged in and continuously powered
    - Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)

  • Short summary description Tripp Lite TAA-Compliant 11kW 3-Phase Monitored PDU, 220/230V (30-C13 & 6-C19), IEC-309 16A Red, 380/400V Input, 10ft Cord, 0U Vertical :

    Tripp Lite TAA-Compliant 11kW 3-Phase Monitored PDU, 220/230V (30-C13 & 6-C19), IEC-309 16A Red, 380/400V Input, 10ft Cord, 0U Vertical, Monitored, 0U, Three-phase, Vertical, Steel, Black

  • Long summary description Tripp Lite TAA-Compliant 11kW 3-Phase Monitored PDU, 220/230V (30-C13 & 6-C19), IEC-309 16A Red, 380/400V Input, 10ft Cord, 0U Vertical :

    Tripp Lite TAA-Compliant 11kW 3-Phase Monitored PDU, 220/230V (30-C13 & 6-C19), IEC-309 16A Red, 380/400V Input, 10ft Cord, 0U Vertical. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: C13 coupler, Power plug: IEC309. Certification: TAA, CE. Monitoring: Humidity, Temperature, Management protocols: HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, Telnet, SSH, FTP, DHCP, BOOTP, NTP. Nominal input voltage: 380-400 V, Maximum current: 16 A, AC input frequency: 50 - 60 Hz

Specs
Design
PDU types Monitored
Type Three-phase
Rack capacity 0U
Mounting Vertical
Housing material Steel
Product colour Black
Display LCD
Ports & interfaces
AC outlets quantity 36 AC outlet(s)
Power plug IEC309
AC outlet types C13 coupler
Ethernet LAN (RJ-45) ports 3
Features
Certification TAA, CE
Management features
Monitoring Humidity, Temperature
Management protocols HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, Telnet, SSH, FTP, DHCP, BOOTP, NTP
Firmware upgradeable

Power
Nominal input voltage 380-400 V
AC input frequency 50 - 60 Hz
Maximum current 16 A
Nominal output voltage 220-230 V
Weight & dimensions
Dimensions (WxDxH) 55.63 x 90.93 x 1778 mm
Weight 5.71 kg
Packaging data
Package dimensions (WxDxH) 245.1 x 1928 x 182.9 mm
Package weight 8.98 kg
Packaging content
Manual
Operational conditions
Operating relative humidity (H-H) 0 - 95%
Technical details
Sustainability certificates RoHS
Compliance certificates RoHS